summaryrefslogtreecommitdiffstats
diff options
context:
space:
mode:
-rw-r--r--WHATS_NEW1
-rw-r--r--daemons/dmeventd/plugins/raid/dmeventd_raid.c37
-rw-r--r--doc/example.conf.in26
-rw-r--r--doc/lvm2-raid.txt71
-rw-r--r--doc/lvm_fault_handling.txt101
-rw-r--r--lib/config/defaults.h1
-rw-r--r--tools/lvconvert.c54
7 files changed, 227 insertions, 64 deletions
diff --git a/WHATS_NEW b/WHATS_NEW
index f2b6efe1..67086570 100644
--- a/WHATS_NEW
+++ b/WHATS_NEW
@@ -1,5 +1,6 @@
Version 2.02.89 -
==================================
+ Add policy based automated repair of RAID logical volumes
Don't allow two images to be split and tracked from a RAID LV at one time
Don't allow size change of RAID LV that is tracking changes for a split image
Don't allow size change of RAID sub-LVs independently
diff --git a/daemons/dmeventd/plugins/raid/dmeventd_raid.c b/daemons/dmeventd/plugins/raid/dmeventd_raid.c
index 71820c29..dd5e7eb0 100644
--- a/daemons/dmeventd/plugins/raid/dmeventd_raid.c
+++ b/daemons/dmeventd/plugins/raid/dmeventd_raid.c
@@ -24,6 +24,41 @@
/* FIXME Replace most syslogs with log_error() style messages and add complete context. */
/* FIXME Reformat to 80 char lines. */
+/*
+ * run_repair is a close copy to
+ * plugins/mirror/dmeventd_mirror.c:_remove_failed_devices()
+ */
+static int run_repair(const char *device)
+{
+ int r;
+#define CMD_SIZE 256 /* FIXME Use system restriction */
+ char cmd_str[CMD_SIZE];
+ char *vg = NULL, *lv = NULL, *layer = NULL;
+
+ if (strlen(device) > 200) /* FIXME Use real restriction */
+ return -1;
+
+ if (!dm_split_lvm_name(dmeventd_lvm2_pool(), device, &vg, &lv, &layer)) {
+ syslog(LOG_ERR, "Unable to determine VG name from %s.",
+ device);
+ return -1;
+ }
+
+ /* FIXME Is any sanity-checking required on %s? */
+ if (CMD_SIZE <= snprintf(cmd_str, CMD_SIZE, "lvconvert --config devices{ignore_suspended_devices=1} --repair --use-policies %s/%s", vg, lv)) {
+ /* this error should be caught above, but doesn't hurt to check again */
+ syslog(LOG_ERR, "Unable to form LVM command: Device name too long.");
+ return -1;
+ }
+
+ r = dmeventd_lvm2_run(cmd_str);
+
+ if (r != ECMD_PROCESSED)
+ syslog(LOG_INFO, "Repair of RAID LV %s/%s failed.", vg, lv);
+
+ return (r == ECMD_PROCESSED) ? 0 : -1;
+}
+
static int _process_raid_event(char *params, const char *device)
{
int i, n, failure = 0;
@@ -71,7 +106,7 @@ static int _process_raid_event(char *params, const char *device)
break;
}
if (failure)
- return 0; /* Don't bother parsing rest of status */
+ return run_repair(device);
}
p = strstr(resync_ratio, "/");
diff --git a/doc/example.conf.in b/doc/example.conf.in
index 72005e98..223f273d 100644
--- a/doc/example.conf.in
+++ b/doc/example.conf.in
@@ -522,9 +522,31 @@ activation {
# "auto" - Use default value chosen by kernel.
readahead = "auto"
+ # 'raid_fault_policy' defines how a device failure in a RAID logical
+ # volume is handled. This includes logical volumes that have the following
+ # segment types: raid1, raid4, raid5*, and raid6*.
+ #
+ # In the event of a failure, the following policies will determine what
+ # actions are performed during the automated response to failures (when
+ # dmeventd is monitoring the RAID logical volume) and when 'lvconvert' is
+ # called manually with the options '--repair' and '--use-policies'.
+ #
+ # "warn" - Use the system log to warn the user that a device in the RAID
+ # logical volume has failed. It is left to the user to run
+ # 'lvconvert --repair' manually to remove or replace the failed
+ # device. As long as the number of failed devices does not
+ # exceed the redundancy of the logical volume (1 device for
+ # raid4/5, 2 for raid6, etc) the logical volume will remain
+ # usable.
+ #
+ # "allocate" - Attempt to use any extra physical volumes in the volume
+ # group as spares and replace faulty devices.
+ #
+ raid_fault_policy = "warn"
+
# 'mirror_image_fault_policy' and 'mirror_log_fault_policy' define
- # how a device failure affecting a mirror is handled.
- # A mirror is composed of mirror images (copies) and a log.
+ # how a device failure affecting a mirror (of "mirror" segment type) is
+ # handled. A mirror is composed of mirror images (copies) and a log.
# A disk log ensures that a mirror does not need to be re-synced
# (all copies made the same) every time a machine reboots or crashes.
#
diff --git a/doc/lvm2-raid.txt b/doc/lvm2-raid.txt
index 4bfc0098..a6f09154 100644
--- a/doc/lvm2-raid.txt
+++ b/doc/lvm2-raid.txt
@@ -380,7 +380,7 @@ until all possible changes have been made. This reduces the likelyhood of bad
intermediate stages being left due to a failure of operation or machine crash.
RAID1 '--splitmirrors', '--trackchanges', and '--merge' operations
------------------------------------------------------------------
+------------------------------------------------------------------
This suite of operations is only available to the "raid1" segment type.
Splitting an image from a RAID1 array is almost identical to the removal of
@@ -404,3 +404,72 @@ set as "hidden" again. Recycling the array (suspend/resume) restores the sub-LV
to its position in the array and begins the process of sync'ing the changes that
were made since the time it was split from the array.
+RAID device replacement with '--replace'
+----------------------------------------
+This option is available to all RAID segment types.
+
+The '--replace' option can be used to remove a particular device from a RAID
+logical volume and replace it with a different one in one action (CLI command).
+The device device to be removed is specified as the argument to the '--replace'
+option. This option can be specified more than once in a single command,
+allowing multiple devices to be replaced at the same time - provided the RAID
+logical volume has the necessary redundancy to allow the action. The devices
+to be used as replacements can also be specified in the command; similar to the
+way allocatable devices are specified during an up-convert.
+
+Example> lvconvert --replace /dev/sdd1 --replace /dev/sde1 vg/lv /dev/sd[bc]1
+
+RAID '--repair'
+---------------
+This 'lvconvert' option is available to all RAID segment types and is described
+under "RAID Fault Handling".
+
+
+RAID Fault Handling
+===================
+RAID is not like traditional LVM mirroring (i.e. the "mirror" segment type).
+LVM mirroring required failed devices to be removed or the logical volume would
+simply hang. RAID arrays can keep on running with failed devices. In fact, for
+RAID types other than RAID1 removing a device would mean substituting an error
+target or converting to a lower level RAID (e.g. RAID6 -> RAID5, or RAID4/5 to
+RAID0). Therefore, rather than removing a failed device unconditionally, the
+user has a couple of options to choose from.
+
+The automated response to a device failure is handled according to the user's
+preference defined in lvm.conf:activation.raid_fault_policy. The options are:
+ # "warn" - Use the system log to warn the user that a device in the RAID
+ # logical volume has failed. It is left to the user to run
+ # 'lvconvert --repair' manually to remove or replace the failed
+ # device. As long as the number of failed devices does not
+ # exceed the redundancy of the logical volume (1 device for
+ # raid4/5, 2 for raid6, etc) the logical volume will remain
+ # usable.
+ #
+ # "remove" - NOT CURRENTLY IMPLEMENTED OR DOCUMENTED IN example.conf.in.
+ # Remove the failed device and reduce the RAID logical volume
+ # accordingly. If a single device dies in a 3-way mirror,
+ # remove it and reduce the mirror to 2-way. If a single device
+ # dies in a RAID 4/5 logical volume, reshape it to a striped
+ # volume, etc - RAID 6 -> RAID 4/5 -> RAID 0. If devices
+ # cannot be removed for lack of redundancy, fail.
+ # THIS OPTION CANNOT YET BE IMPLEMENTED BECAUSE RESHAPE IS NOT
+ # YET SUPPORTED IN linux/drivers/md/dm-raid.c. The superblock
+ # does not yet hold enough information to support reshaping.
+ #
+ # "allocate" - Attempt to use any extra physical volumes in the volume
+ # group as spares and replace faulty devices.
+
+If manual intervention is taken, either in response to the automated solution's
+"warn" mode or simply because dmeventd hadn't run, then the user can call
+'lvconvert --repair vg/lv' and follow the prompts. They will be prompted
+whether or not to replace the device and cause a full recovery of the failed
+device.
+
+If replacement is chosen via the manual method or "allocate" is the policy taken
+by the automated response, then 'lvconvert --replace' is the mechanism used to
+attempt the replacement of the failed device.
+
+'vgreduce --removemissing' is ineffectual at repairing RAID logical volumes. It
+will remove the failed device, but the RAID logical volume will simply continue
+to operate with an <unknown> sub-LV. The user should clear the failed device
+with 'lvconvert --repair'.
diff --git a/doc/lvm_fault_handling.txt b/doc/lvm_fault_handling.txt
index fa30c0c2..53b447ea 100644
--- a/doc/lvm_fault_handling.txt
+++ b/doc/lvm_fault_handling.txt
@@ -15,6 +15,12 @@ from (e.g. a power failure, intermittent network outage, block
relocation, etc). The policies for handling both types of failures
is described herein.
+Users need to be aware that there are two implementations of RAID1 in LVM.
+The first is defined by the "mirror" segment type. The second is defined by
+the "raid1" segment type. The characteristics of each of these are defined
+in lvm.conf under 'mirror_segtype_default' - the configuration setting used to
+identify the default RAID1 implementation used for LVM operations.
+
Available Operations During a Device Failure
--------------------------------------------
When there is a device failure, LVM behaves somewhat differently because
@@ -51,30 +57,36 @@ are as follows:
a linear, stripe, or snapshot device is located on the failed device
the command will not proceed without a '--force' option. The result
of using the '--force' option is the entire removal and complete
- loss of the non-redundant logical volume. Once this operation is
- complete, the volume group will again have a complete and consistent
- view of the devices it contains. Thus, all operations will be
- permitted - including creation, conversion, and resizing operations.
+ loss of the non-redundant logical volume. If an image or metadata area
+ of a RAID logical volume is on the failed device, the sub-LV affected is
+ replace with an error target device - appearing as <unknown> in 'lvs'
+ output. RAID logical volumes cannot be completely repaired by vgreduce -
+ 'lvconvert --repair' (listed below) must be used. Once this operation is
+ complete on volume groups not containing RAID logical volumes, the volume
+ group will again have a complete and consistent view of the devices it
+ contains. Thus, all operations will be permitted - including creation,
+ conversion, and resizing operations. It is currently the preferred method
+ to call 'lvconvert --repair' on the individual logical volumes to repair
+ them followed by 'vgreduce --removemissing' to extract the physical volume's
+ representation in the volume group.
- 'lvconvert --repair <VG/LV>': This action is designed specifically
- to operate on mirrored logical volumes. It is used on logical volumes
- individually and does not remove the faulty device from the volume
- group. If, for example, a failed device happened to contain the
- images of four distinct mirrors, it would be necessary to run
- 'lvconvert --repair' on each of them. The ultimate result is to leave
- the faulty device in the volume group, but have no logical volumes
- referencing it. In addition to removing mirror images that reside
- on failed devices, 'lvconvert --repair' can also replace the failed
- device if there are spare devices available in the volume group. The
- user is prompted whether to simply remove the failed portions of the
- mirror or to also allocate a replacement, if run from the command-line.
- Optionally, the '--use-policies' flag can be specified which will
- cause the operation not to prompt the user, but instead respect
+ to operate on individual logical volumes. If, for example, a failed
+ device happened to contain the images of four distinct mirrors, it would
+ be necessary to run 'lvconvert --repair' on each of them. The ultimate
+ result is to leave the faulty device in the volume group, but have no logical
+ volumes referencing it. (This allows for 'vgreduce --removemissing' to
+ removed the physical volumes cleanly.) In addition to removing mirror or
+ RAID images that reside on failed devices, 'lvconvert --repair' can also
+ replace the failed device if there are spare devices available in the
+ volume group. The user is prompted whether to simply remove the failed
+ portions of the mirror or to also allocate a replacement, if run from the
+ command-line. Optionally, the '--use-policies' flag can be specified which
+ will cause the operation not to prompt the user, but instead respect
the policies outlined in the LVM configuration file - usually,
- /etc/lvm/lvm.conf. Once this operation is complete, mirrored logical
- volumes will be consistent and I/O will be allowed to continue.
- However, the volume group will still be inconsistent - due to the
- refernced-but-missing device/PV - and operations will still be
+ /etc/lvm/lvm.conf. Once this operation is complete, the logical volumes
+ will be consistent. However, the volume group will still be inconsistent -
+ due to the refernced-but-missing device/PV - and operations will still be
restricted to the aformentioned actions until either the device is
restored or 'vgreduce --removemissing' is run.
@@ -98,13 +110,15 @@ following possible exceptions exist:
Automated Target Response to Failures:
--------------------------------------
-The only LVM target type (i.e. "personality") that has an automated
-response to failures is a mirrored logical volume. The other target
+The only LVM target types (i.e. "personalities") that have an automated
+response to failures are the mirror and RAID logical volumes. The other target
types (linear, stripe, snapshot, etc) will simply propagate the failure.
[A snapshot becomes invalid if its underlying device fails, but the
origin will remain valid - presuming the origin device has not failed.]
-There are three types of errors that a mirror can suffer - read, write,
-and resynchronization errors. Each is described in depth below.
+
+Starting with the "mirror" segment type, there are three types of errors that
+a mirror can suffer - read, write, and resynchronization errors. Each is
+described in depth below.
Mirror read failures:
If a mirror is 'in-sync' (i.e. all images have been initialized and
@@ -184,38 +198,5 @@ command are set in the LVM configuration file. They are:
choice of when to incure the extra performance costs of replacing
the failed image.
-TODO...
-The appropriate time to take permanent corrective action on a mirror
-should be driven by policy. There should be a directive that takes
-a time or percentage argument. Something like the following:
-- mirror_fault_policy_WHEN = "10sec"/"10%"
-A time value would signal the amount of time to wait for transient
-failures to resolve themselves. The percentage value would signal the
-amount a mirror could become out-of-sync before the faulty device is
-removed.
-
-A mirror cannot be used unless /some/ corrective action is taken,
-however. One option is to replace the failed mirror image with an
-error target, forgo the use of 'handle_errors', and simply let the
-out-of-sync regions accumulate and be tracked by the log. Mirrors
-that have more than 2 images would have to "stack" to perform the
-tracking, as each failed image would have to be associated with a
-log. If the failure is transient, the device would replace the
-error target that was holding its spot and the log that was tracking
-the deltas would be used to quickly restore the portions that changed.
-
-One unresolved issue with the above scheme is how to know which
-regions of the mirror are out-of-sync when a problem occurs. When
-a write failure occurs in the kernel, the log will contain those
-regions that are not in-sync. If the log is a disk log, that log
-could continue to be used to track differences. However, if the
-log was a core log - or if the log device failed at the same time
-as an image device - there would be no way to determine which
-regions are out-of-sync to begin with as we start to track the
-deltas for the failed image. I don't have a solution for this
-problem other than to only be able to handle errors in this way
-if conditions are right. These issues will have to be ironed out
-before proceeding. This could be another case, where it is better
-to handle failures in the kernel by allowing the kernel to store
-updates in various metadata areas.
-...TODO
+RAID logical volume device failures are handled differently from the "mirror"
+segment type. Discussion of this can be found in lvm2-raid.txt.
diff --git a/lib/config/defaults.h b/lib/config/defaults.h
index 27acf8ab..a86016ea 100644
--- a/lib/config/defaults.h
+++ b/lib/config/defaults.h
@@ -55,6 +55,7 @@
#define DEFAULT_MIRROR_LOG_FAULT_POLICY "allocate"
#define DEFAULT_MIRROR_IMAGE_FAULT_POLICY "remove"
#define DEFAULT_MIRROR_MAX_IMAGES 8 /* limited by kernel DM_KCOPYD_MAX_REGIONS */
+#define DEFAULT_RAID_FAULT_POLICY "warn"
#define DEFAULT_DMEVENTD_RAID_LIB "libdevmapper-event-lvm2raid.so"
#define DEFAULT_DMEVENTD_MIRROR_LIB "libdevmapper-event-lvm2mirror.so"
#define DEFAULT_DMEVENTD_SNAPSHOT_LIB "libdevmapper-event-lvm2snapshot.so"
diff --git a/tools/lvconvert.c b/tools/lvconvert.c
index 1b9f6f9b..2b84de4c 100644
--- a/tools/lvconvert.c
+++ b/tools/lvconvert.c
@@ -1424,9 +1424,44 @@ static int is_valid_raid_conversion(const struct segment_type *from_segtype,
return 1;
}
+static void _lvconvert_raid_repair_ask(struct cmd_context *cmd, int *replace_dev)
+{
+ const char *dev_policy = NULL;
+
+ int force = arg_count(cmd, force_ARG);
+ int yes = arg_count(cmd, yes_ARG);
+
+ *replace_dev = 0;
+
+ if (arg_count(cmd, use_policies_ARG)) {
+ dev_policy = find_config_tree_str(cmd, "activation/raid_fault_policy", DEFAULT_RAID_FAULT_POLICY);
+
+ if (!strcmp(dev_policy, "allocate") ||
+ !strcmp(dev_policy, "replace"))
+ *replace_dev = 1;
+ /* else if (!strcmp(dev_policy, "anything_else")) -- ignore */
+ return;
+ }
+
+ if (yes) {
+ *replace_dev = 1;
+ return;
+ }
+
+ if (force != PROMPT)
+ return;
+
+ if (yes_no_prompt("Attempt to replace failed RAID images "
+ "(requires full device resync)? [y/n]: ") == 'y') {
+ *replace_dev = 1;
+ }
+}
+
static int lvconvert_raid(struct logical_volume *lv, struct lvconvert_params *lp)
{
+ int replace = 0;
int image_count;
+ struct dm_list *failed_pvs;
struct cmd_context *cmd = lv->vg->cmd;
struct lv_segment *seg = first_seg(lv);
@@ -1485,6 +1520,25 @@ static int lvconvert_raid(struct logical_volume *lv, struct lvconvert_params *lp
if (arg_count(cmd, replace_ARG))
return lv_raid_replace(lv, lp->replace_pvh, lp->pvh);
+ if (arg_count(cmd, repair_ARG)) {
+ _lvconvert_raid_repair_ask(cmd, &replace);
+
+ if (replace) {
+ if (!(failed_pvs = _failed_pv_list(lv->vg))) {
+ stack;
+ return ECMD_FAILED;
+ }
+ return lv_raid_replace(lv, failed_pvs, lp->pvh);
+ }
+
+ /* "warn" if policy not set to replace */
+ if (arg_count(cmd, use_policies_ARG))
+ log_error("Issue 'lvconvert --repair %s/%s' to "
+ "replace failed device",
+ lv->vg->name, lv->name);
+ return 1;
+ }
+
log_error("Conversion operation not yet supported.");
return 0;
}