.\" -*- nroff -*-
-.TH MDADM 8 "" v1.5.0
+.TH MDADM 8 "" v1.6.0
.SH NAME
mdadm \- manage MD devices
.I aka
@@ -76,7 +76,7 @@ configuration file, at all. It has a different configuration file
with a different format and an different purpose.
.SH MODES
-mdadm has 6 major modes of operation:
+mdadm has 7 major modes of operation:
.TP
.B Assemble
Assemble the parts of a previously created
@@ -114,6 +114,12 @@ only meaningful for raid1, 4, 5, 6 or multipath arrays as
only these have interesting state. raid0 or linear never have
missing, spare, or failed drives, so there is nothing to monitor.
+.TP
+.B "Grow"
+Grow (or shrink) an array, or otherwise reshape it in some way.
+Currently supported growth options including changing the active size
+of componenet devices in RAID level 1/4/5/6 and changing the number of
+active devices in RAID1.
.SH OPTIONS
@@ -153,6 +159,10 @@ Select
mode.
.TP
+.BR -G ", " --grow
+Change the size or shape of an active array.
+
+.TP
.BR -h ", " --help
Display help message or, after above option, mode specific help
message.
@@ -261,13 +271,17 @@ Specify the number of active devices in the array. This, plus the
number of spare devices (see below) must equal the number of
.I component-devices
(including "\fBmissing\fP" devices)
-that are listed on the command line. Setting a value of 1 is probably
+that are listed on the command line for
+.BR --create .
+Setting a value of 1 is probably
a mistake and so requires that
.B --force
be specified first. A value of 1 will then be allowed for linear,
multipath, raid0 and raid1. It is never allowed for raid4 or raid5.
.br
-Note that this number cannot be changed once the array has been created.
+This number can only be changed using
+.B --grow
+for RAID1 arrays, and only on kernels which provide necessary support.
.TP
.BR -x ", " --spare-devices=
@@ -288,6 +302,63 @@ If this is not specified
size, though if there is a variance among the drives of greater than 1%, a warning is
issued.
+This value can be set with
+.B --grow
+for RAID level 1/4/5/6. If the array was created with a size smaller
+than the currently active drives, the extra space can be accessed
+using
+.BR --grow .
+
+.TP
+.BR --assume-clean
+Tell
+.I mdadm
+that the array pre-existed and is known to be clean. This is only
+really useful for Building RAID1 array. Only use this if you really
+know what you are doing. This is currently only supported for --build.
+
+.TP
+.BR -R ", " --run
+Insist that
+.I mdadm
+run the array, even if some of the components
+appear to be active in another array or filesystem. Normally
+.I mdadm
+will ask for confirmation before including such components in an
+array. This option causes that question to be suppressed.
+
+.TP
+.BR -f ", " --force
+Insist that
+.I mdadm
+accept the geometry and layout specified without question. Normally
+.I mdadm
+will not allow creation of an array with only one device, and will try
+to create a raid5 array with one missing drive (as this makes the
+initial resync work faster). With
+.BR --force ,
+.I mdadm
+will not try to be so clever.
+
+.TP
+.BR -a ", " "--auto{=no,yes,md,mdp,part,p}{NN}"
+Instruct mdadm to create the device file if needed, and to allocate
+an unused minor number. "yes" or "md" causes a non-partitionable array
+to be used. "mdp", "part" or "p" causes a partitionable array (2.6 and
+later) to be used. The argumentment can also come immediately after
+"-a". e.g. "-ap".
+
+For partitionable arrays,
+.I mdadm
+will create the device file for the whole array and for the first 4
+partitions. A different number of partitions can be specified at the
+end of this option (e.g.
+.BR --auto=p7 ).
+If the device name ends with a digit, the partition names add an
+underscore, a 'p', and a number, e.g. "/dev/home1_p3". If there is no
+trailing digit, then the partition names just have a number added,
+e.g. "/dev/scratch3".
+
.SH For assemble:
.TP
@@ -327,6 +398,10 @@ With
an attempt will be made to start it anyway.
.TP
+.BR -a ", " "--auto{=no,yes,md,mdp,part}"
+See this option under Create and Build options.
+
+.TP
.BR -U ", " --update=
Update the superblock on each device while assembling the array. The
argument given to this flag can be one of
@@ -504,7 +579,7 @@ listed in the configuration file are assembled.
If precisely one device is listed, but
.B --scan
-is not given, that
+is not given, then
.I mdadm
acts as though
.B --scan
@@ -545,6 +620,46 @@ may work for RAID1, 4, 5 or 6), give the
.B --run
flag.
+If an
+.B auto
+option is given, either on the command line (--auto) or in the
+configuration file (e.g. auto=part), then
+.I mdadm
+will create the md device if necessary or will re-create it if it
+doesn't look usable as it is.
+
+This can be useful for handling partitioned devices (which don't have
+a stable device number - it can change after a reboot) and when using
+"udev" to manage your
+.B /dev
+tree (udev cannot handle md devices because of the unusual device
+initialisation conventions).
+
+If the option to "auto" is "mdp" or "part" or (on the command line
+only) "p", then mdadm will create a partitionable array, using the
+first free one that is not inuse, and does not already have an entry
+in /dev (apart from numeric /dev/md* entries).
+
+If the option to "auto" is "yes" or "md" or (on the command line)
+nothing, then mdadm will create a traditional, non-partitionable md
+array.
+
+It is expected that the "auto" functionality will be used to create
+device entries with meaningful names such as "/dev/md/home" or
+"/dev/md/root", rather than names based on the numerical array number.
+
+When using this option to create a partitionable array, the device
+files for the first 4 partitions are also created. If a different
+number is required it can be simply appended to the auto option.
+e.g. "auto=part8". Partition names are created by appending a digit
+string to the device name, with an intervening "_p" if the device name
+ends with a digit.
+
+The
+.B --auto
+option is also available in Build and Create modes. As those modes do
+not use a config file, the "auto=" config option does not apply to
+these modes.
.SH BUILD MODE
@@ -584,6 +699,12 @@ Usage:
This usage will initialise a new md array, associate some devices with
it, and activate the array.
+This the
+.B --auto
+option is given (as described in more detail in the section on
+Assemble mode), then the md device will be created with a suitable
+device number if necessary.
+
As devices are added, they are checked to see if they contain raid
superblocks or filesystems. They are also checked to see if the variance in
device size exceeds 1%.
@@ -625,7 +746,7 @@ option.
The General Management options that are valid with --create are:
.TP
.B --run
-insist of running the array even if some devices look like they might
+insist on running the array even if some devices look like they might
be in use.
.TP
@@ -921,6 +1042,43 @@ first.
If the removal succeeds but the adding fails, then it is added back to
the original array.
+.SH GROW MODE
+The GROW mode is used for changing the size or shape of an active
+array.
+For this to work, the kernel must support the necessary change.
+Various types of growth may be added during 2.6 development, possibly
+including restructuring a raid5 array to have more active devices.
+
+Currently the only support available is to change the "size" attribute
+for arrays with redundancy, and the raid-disks attribute of RAID1
+arrays.
+
+Normally when an array is build the "size" it taken from the smallest
+of the drives. If all the small drives in an arrays are, one at a
+time, removed and replaced with larger drives, then you could have an
+array of large drives with only a small amount used. In this
+situation, changing the "size" with "GROW" mode will allow the extra
+space to start being used. If the size is increased in this way, a
+"resync" process will start to make sure the new parts of the array
+are synchronised.
+
+Note that when an array changes size, any filesystem that may be
+stored in the array will not automatically grow to use the space. The
+filesystem will need to be explicitly told to use the extra space.
+
+A RAID1 array can work with any number of devices from 1 upwards
+(though 1 is not very useful). There may be times which you want to
+increase or decrease the number of active devices. Note that this is
+different to hot-add or hot-remove which changes the number of
+inactive devices.
+
+When reducing the number of devices in a RAID1 array, the slots which
+are to be removed from the array must already be vacant. That is, the
+devices that which were in those slots must be failed and removed.
+
+When the number of devices is increased, any hot spares that are
+present may be activated immediately.
+
.SH EXAMPLES
.B " mdadm --query /dev/name-of-device"