diff options
author | Neil Brown <neilb@suse.de> | 2005-12-05 05:55:56 +0000 |
---|---|---|
committer | Neil Brown <neilb@suse.de> | 2005-12-05 05:55:56 +0000 |
commit | 773135f5bdf57219bf7f957b86964ba40d041180 (patch) | |
tree | a4d6248d3df1e4a101489f4d5696078db8009fbb /mdadm.8 | |
parent | fe394e5e4237e9c4d36a9a507ae36e5874ec66c4 (diff) | |
download | mdadm-773135f5bdf57219bf7f957b86964ba40d041180.tar.gz mdadm-773135f5bdf57219bf7f957b86964ba40d041180.tar.xz mdadm-773135f5bdf57219bf7f957b86964ba40d041180.zip |
syslog support for monitor mode
From: ross@jose.lug.udel.edu (Ross Vandegrift)
Hi Neil,
While adding the text message mode, I saw a FIXME asking for syslog
support in monitor mode.
This patch adds exactly that.
Signed-off-by: Neil Brown <neilb@suse.de>
Diffstat (limited to 'mdadm.8')
-rw-r--r-- | mdadm.8 | 25 |
1 files changed, 18 insertions, 7 deletions
@@ -751,6 +751,11 @@ Give a mail address to send alerts to. Give a program to be run whenever an event is detected. .TP +.BR -y ", " --syslog +Cause all events to be reported through 'syslog'. The messages have +facility of 'daemon' and varying priorities. + +.TP .BR -d ", " --delay Give a delay in seconds. .B mdadm @@ -1189,7 +1194,7 @@ The different events are: .TP .B DeviceDisappeared An md array which previously was configured appears to no longer be -configured. +configured. (syslog priority: Critical) If .I mdadm @@ -1203,39 +1208,41 @@ hot-spare and resync operations which are monitored. .TP .B RebuildStarted -An md array started reconstruction. +An md array started reconstruction. (syslog priority: Warning) .TP .BI Rebuild NN Where .I NN is 20, 40, 60, or 80, this indicates that rebuild has passed that many -percentage of the total. +percentage of the total. (syslog priority: Warning) .TP .B RebuildFinished An md array that was rebuilding, isn't any more, either because it -finished normally or was aborted. +finished normally or was aborted. (syslog priority: Warning) .TP .B Fail -An active component device of an array has been marked as faulty. +An active component device of an array has been marked as +faulty. (syslog priority: Critical) .TP .B FailSpare A spare component device which was being rebuilt to replace a faulty -device has failed. +device has failed. (syslog priority: Critial) .TP .B SpareActive A spare component device which was being rebuilt to replace a faulty device as been successfully rebuild and has been made active. +(syslog priority: Info) .TP .B NewArray A new md array has been detected in the .B /proc/mdstat -file. +file. (syslog priority: Info) .TP .B DegradedArray @@ -1245,12 +1252,14 @@ generated when notices a drive failure which causes degradation, but only when .I mdadm notices that an array is degraded when it first sees the array. +(syslog priority: Critial) .TP .B MoveSpare A spare drive has been moved from one array in a .B spare-group to another to allow a failed drive to be replaced. +(syslog priority: Info) .TP .B SparesMissing @@ -1263,12 +1272,14 @@ detects that it has fewer that this number when it first sees the array, it will report a .B SparesMissing message. +(syslog priority: Info) .TP .B TestMessage An array was found at startup, and the .B --test flag was given. +(syslog priority: Info) .RE Only |