diff options
author | Kaleb S KEITHLEY <kkeithle@redhat.com> | 2015-12-14 09:24:57 -0500 |
---|---|---|
committer | Kaleb KEITHLEY <kkeithle@redhat.com> | 2016-03-14 21:34:27 -0700 |
commit | 40a24f5ab917863d1549508ae9cf31085955d174 (patch) | |
tree | 04568d9bb2c39b6ad9abc5059d298b3457a65f6a /doc/features | |
parent | 7240923a55eab2fc237d951ec0d89c51676a2aae (diff) | |
download | glusterfs-40a24f5ab917863d1549508ae9cf31085955d174.tar.gz glusterfs-40a24f5ab917863d1549508ae9cf31085955d174.tar.xz glusterfs-40a24f5ab917863d1549508ae9cf31085955d174.zip |
common-ha: reliable grace using pacemaker notify actions
Using *-dead_ip-1 resources to track on which nodes the ganesha.nfsd
had died was found to be unreliable.
Running `pcs status` in the ganesha_grace monitor action was seen to
time out during failover; the HA devs opined that it was, generally,
not a good idea to run `pcs status` in a monitor action in any event.
They suggested using the notify feature, where the resources on all
the nodes are notified when a clone resource agent dies.
This change adds a notify action to the ganesha_grace RA. The ganesha_mon
RA monitors its ganesha.nfsd daemon. While the daemon is running, it
creates two attributes: ganesha-active and grace-active. When the daemon
stops for any reason, the attributes are deleted. Deleting the
ganesha-active attribute triggers the failover of the virtual IP (the
IPaddr RA) to another node where ganesha.nfsd is still running. The
ganesha_grace RA monitors the grace-active attribute. When the
grace-active attibute is deleted, the ganesha_grace RA stops, and will
not restart. This triggers pacemaker to trigger the notify action in
the ganesha_grace RAs on the other nodes in the cluster; which send a
DBUS message to their ganesha.nfsd.
(N.B. grace-active is a bit of a misnomer. while the grace-active
attribute exists, everything is normal and healthy. Deleting the
attribute triggers putting the surviving ganesha.nfsds into GRACE.)
To ensure that the remaining/surviving ganesha.nfsds are put into
NFS-GRACE before the IPaddr (virtual IP) fails over there is a short
delay (sleep) between deleting the grace-active attribute and the
ganesha-active attribute. To summarize:
1. on node 2 ganesha_mon:monitor notices that ganesha.nfsd has died
2. on node 2 ganesha_mon:monitor deletes its grace-active attribute
3. on node 2 ganesha_grace:monitor notices that grace-active is gone
and returns OCF_ERR_GENERIC, a.k.a. new error. When pacemaker
tries to (re)start ganesha_grace, its start action will return
OCF_NOT_RUNNING, a.k.a. known error, don't attempt further
restarts.
4. on nodes 1, 3, etc., ganesha_grace:notify receives a post-stop
notification indicating that node 2 is gone, and sends a DBUS
message to its ganesha.nfsd putting it into NFS-GRACE.
5. on node 2 ganesha_mon:monitor waits a short period, then deletes
its ganesha-active attribute. This triggers the IPaddr (virt IP)
failover according to constraint location rules.
ganesha_nfsd modified to run for the duration, start action is invoked
to setup the /var/lib/nfs symlink, stop action is invoked to restore it.
ganesha-ha.sh modified accordingly to create it as a clone resource.
BUG: 1290865
Change-Id: I1ba24f38fa4338b3aeb17c65645e9f439387ff57
Signed-off-by: Kaleb S KEITHLEY <kkeithle@redhat.com>
Reviewed-on: http://review.gluster.org/12964
Smoke: Gluster Build System <jenkins@build.gluster.com>
NetBSD-regression: NetBSD Build System <jenkins@build.gluster.org>
CentOS-regression: Gluster Build System <jenkins@build.gluster.com>
Reviewed-on: http://review.gluster.org/13725
Diffstat (limited to 'doc/features')
-rw-r--r-- | doc/features/ganesha-ha.md | 43 |
1 files changed, 43 insertions, 0 deletions
diff --git a/doc/features/ganesha-ha.md b/doc/features/ganesha-ha.md new file mode 100644 index 0000000000..4b226a22cc --- /dev/null +++ b/doc/features/ganesha-ha.md @@ -0,0 +1,43 @@ +# Overview of Ganesha HA Resource Agents in GlusterFS 3.7 + +The ganesha_mon RA monitors its ganesha.nfsd daemon. While the +daemon is running, it creates two attributes: ganesha-active and +grace-active. When the daemon stops for any reason, the attributes +are deleted. Deleting the ganesha-active attribute triggers the +failover of the virtual IP (the IPaddr RA) to another node — +according to constraint location rules — where ganesha.nfsd is +still running. + +The ganesha_grace RA monitors the grace-active attribute. When +the grace-active attibute is deleted, the ganesha_grace RA stops, +and will not restart. This triggers pacemaker to invoke the notify +action in the ganesha_grace RAs on the other nodes in the cluster; +which send a DBUS message to their respective ganesha.nfsd. + +(N.B. grace-active is a bit of a misnomer. while the grace-active +attribute exists, everything is normal and healthy. Deleting the +attribute triggers putting the surviving ganesha.nfsds into GRACE.) + +To ensure that the remaining/surviving ganesha.nfsds are put into + NFS-GRACE before the IPaddr (virtual IP) fails over there is a +short delay (sleep) between deleting the grace-active attribute +and the ganesha-active attribute. To summarize, e.g. in a four +node cluster: + +1. on node 2 ganesha_mon::monitor notices that ganesha.nfsd has died + +2. on node 2 ganesha_mon::monitor deletes its grace-active attribute + +3. on node 2 ganesha_grace::monitor notices that grace-active is gone +and returns OCF_ERR_GENERIC, a.k.a. new error. When pacemaker tries +to (re)start ganesha_grace, its start action will return +OCF_NOT_RUNNING, a.k.a. known error, don't attempt further restarts. + +4. on nodes 1, 3, and 4, ganesha_grace::notify receives a post-stop +notification indicating that node 2 is gone, and sends a DBUS message +to its ganesha.nfsd, putting it into NFS-GRACE. + +5. on node 2 ganesha_mon::monitor waits a short period, then deletes +its ganesha-active attribute. This triggers the IPaddr (virt IP) +failover according to constraint location rules. + |