+// Copyright (c) 2007 DMTF. All rights reserved.
+ [Version ( "2.7.0" ),
+ UMLPackagePath ( "CIM::Metrics::UnitOfWork" ),
+ Description (
+ "Each instance of UnitOfWork identifies a transaction that is "
+ "either in-process or already completed. Because instances of "
+ "\'in-process\' UnitsOfWork can be very short-lived and there "
+ "can be a great number of active ones, use of this class as an "
+ "instrumentation source for determining response time may be "
+ "incorrect or inefficient, unless the rate and duration of the "
+ "UnitsOfWork are known. The intended use is to respond to "
+ "queries about currently active or recently completed "
+ "UnitsOfWork. The length of time that a UnitOfWork instance "
+ "exists after the UnitOfWork completes is not defined and "
+ "should be assumed to be implementation-dependent. This class "
+ "is weak to its definition (CIM_UnitOfWorkDefintion)." )]
+class CIM_UnitOfWork : CIM_ManagedElement {
+
+ [Override ( "Description" ),
+ Description (
+ "Since UnitOfWork is designed to be an extremely "
+ "lightweight object, it is recommended that this property "
+ "not be used. The Description specified for the "
+ "instance\'s associated CIM_UnitOfWorkDefintion should "
+ "apply." )]
+ string Description;
+
+ [Key, Description (
+ "The identifier of the UnitOfWork, within the context of "
+ "the UnitOfWorkDefinition." )]
+ sint64 Id;
+
+ [Key, Description (
+ "A 16 byte value that uniquely identifies the UnitOfWork "
+ "Definition. The use of OSF UUID/GUIDs is recommended." ),
+ MaxLen ( 16 ),
+ Propagated ( "CIM_UnitOfWorkDefinition.Id" )]
+ string UoWDefId;
+
+ [Description (
+ "The name of the user who initiated the UnitOfWork. This "
+ "may be a real user\'s login name or a logical name "
+ "representing an application." )]
+ string UserName;
+
+ [Description ( "The time that the UnitOfWork was started." )]
+ datetime StartTime;
+
+ [Description (
+ "The elapsed time since the UnitOfWork was started. Upon "
+ "completion of the UnitOfWork, this property contains the "
+ "total amount of time taken in processing the entire "
+ "UnitOfWork." )]
+ datetime ElapsedTime;
+
+ [Description (
+ "An enumeration identifing the status of the UnitOfWork. "
+ "Most of the property values are self-explanatory, but a "
+ "few need additional text: \n"
+ "3=\"Completed\" - Should be used to represent a "
+ "\'completed\' transaction whose status (\'good\', "
+ "\'failed\' or \'aborted\') is unknown. \n"
+ "6=\"Completed Aborted\" - Should be used when a "
+ "UnitOfWork has completed but was not allowed to end "
+ "normally. An example would be when the Stop or Back "
+ "buttons are selected from a web browser, before a page "
+ "is fully loaded." ),
+ ValueMap { "1", "2", "3", "4", "5", "6" },
+ Values { "Active", "Suspended", "Completed",
+ "Completed Good", "Completed Failed", "Completed Aborted" }]
+ uint16 Status;
+
+ [Description (
+ "Indicates the granularity at which traces are written "
+ "for this particular instance of UnitOfWork. Traces allow "
+ "providing more detailed information on the course of the "
+ "execution of the UnitOfWork than just the status and the "
+ "elapsed time. The trace level does not indicate where "
+ "the traces are found (i.e. in which file or CIM "
+ "instances). TraceLevel cannot be set (i.e. written) "
+ "since an instance of UnitOfWork only publishes "
+ "information. So, the application code that executes the "
+ "unit of work must receive the desired trace level by its "
+ "caller (e.g. the parent module, the user or some remote "
+ "system that initiates the unit of work). \n"
+ "If its value is 0, no traces are available. If its value "
+ "is > 0, traces are available. Except 0, the possible "
+ "values and their semantics are implementation dependent. "
+ "Two instances of UnitOfWork (even with the same "
+ "definition) may have different trace levels since the "
+ "desired or required granularity of traces may be "
+ "dependent on the execution context (detection of an "
+ "error, analysis of an error, etc.) of the unit of work. \n"
+ "The trace level can be encoded as a bit map (each "
+ "individual bit indicates a certain trace type and/or "
+ "level of detail) or numbers (that are further defined by "
+ "a value map). No encoding scheme is imposed since no "
+ "general rules or standards exist and in consequence, "
+ "application developers could reuse their existing trace "
+ "level scheme." )]
+ uint32 TraceLevel;
+
+ [Description (
+ "A string that uniquely identifies the mutual context of "
+ "UnitOfWork instances. The context is defined as an "
+ "individual action that several UnitOfWork instances "
+ "participate in. The use of Ids such as OSF UUID/GUIDs is "
+ "recommended, although some implementations may require "
+ "longer Ids. (This is the reason why no maxlen(16) "
+ "qualifier has been used.) \n"
+ "MutualContextId explicitly identifies the context for "
+ "instances of UnitOfWork, that is otherwise provided "
+ "implicitly by SubUoW association instances. In addition, "
+ "one can query directly (i.e. without following the "
+ "associations) for UnitOfWork instances that participate "
+ "in some individual action (i.e., the mutual context). If "
+ "no mutual context is needed or if it is not supported by "
+ "the implementation, the value is NULL. \n"
+ "Note that the MutualContextId value is to be transferred "
+ "internally between the participating UnitOfWork "
+ "implementations such that each UnitOfWork instance "
+ "implementation receives its value from its "
+ "predecessor/parent or initially creates the value if it "
+ "is the first instance of the context." )]
+ string MutualContextId;
+
+
+};