@@ -0,0 +1,114 @@
+// Copyright (c) 2005 DMTF. All rights reserved.
+// <change cr="CIMCoreCR00735.001" type ="change">Update of
+// descriptions based on Tech Edit review.</
+// <change cr="ArchCR00066.004" type="add">Add UmlPackagePath
+// qualifier values to CIM Schema.</change>
+// <change cr="ArchCR00089.003" type="add">Add PUnit qualifier values
+// to Units qualifier values.</change>
+// ==================================================================
+// CIM_UninterruptiblePowerSupply
+// ==================================================================
+ [Version ( "2.10.0" ),
+ UMLPackagePath ( "CIM::Device::CoolingAndPower" ),
+ Description (
+ "Capabilities and management of an UninterruptiblePowerSupply. "
+ "The properties of the UPS Device indicate when incoming power "
+ "is trimmed or boosted, and the aggregated information of the "
+ "batteries, generators, and so on that comprise the Device. "
+ "These individual components (for example, multiple batteries) "
+ "can also be independently modeled and associated with the UPS." )]
+class CIM_UninterruptiblePowerSupply : CIM_PowerSupply {
+
+ [Override ( "Range1InputVoltageLow" ),
+ Description (
+ "If the voltage (in millivolts) drops below the value "
+ "specified by Range1InputVoltageLow, the UPS will "
+ "compensate by boosting the voltage using its power "
+ "sources. A value of 0 indicates that the voltage at "
+ "which boosting occurs is \'unknown\'." ),
+ Units ( "MilliVolts" ),
+ PUnit ( "volt * 10^-3" )]
+ uint32 Range1InputVoltageLow;
+
+ [Override ( "Range1InputVoltageHigh" ),
+ Description (
+ "If the voltage (in millivolts) rises above the value "
+ "specified by Range1InputVoltageHigh, the UPS will "
+ "compensate by trimming the voltage. A value of 0 "
+ "indicates that the voltage at which trimming occurs is "
+ "\'unknown\'." ),
+ Units ( "MilliVolts" ),
+ PUnit ( "volt * 10^-3" )]
+ uint32 Range1InputVoltageHigh;
+
+ [Override ( "Range2InputVoltageLow" ),
+ Description (
+ "If the voltage (in millivolts) drops below the value "
+ "specified by Range2InputVoltageLow, the UPS will "
+ "compensate by boosting the voltage using its power "
+ "sources. A value of 0 indicates that the voltage at "
+ "which boosting occurs is \'unknown\'." ),
+ Units ( "MilliVolts" ),
+ PUnit ( "volt * 10^-3" )]
+ uint32 Range2InputVoltageLow;
+
+ [Override ( "Range2InputVoltageHigh" ),
+ Description (
+ "If the voltage (in millivolts) rises above the value "
+ "specified by Range2InputVoltageHigh, the UPS will "
+ "compensate by trimming the voltage. A value of 0 "
+ "indicates that the voltage at which trimming occurs is "
+ "\'unknown\'." ),
+ Units ( "MilliVolts" ),
+ PUnit ( "volt * 10^-3" )]
+ uint32 Range2InputVoltageHigh;
+
+ [Description (
+ "The indication of the capacity that remains in the UPS "
+ "batteries, generator, and so on. A value of \"Normal\" "
+ "(2) indicates that the remaining estimated minutes of "
+ "run-time are greater than the \'low power\' state "
+ "defined for the UPS (typically two minutes). A value of "
+ "\"Low\" (3) indicates that the remaining estimated "
+ "minutes of run-time are less than or equal to the "
+ "defined \'low power\' state of the device. A value of "
+ "\"Depleted\" (4) indicates that the UPS will be unable "
+ "to sustain the present load when and if the utility "
+ "power is lost (including the possibility that the "
+ "utility power is currently absent)." ),
+ ValueMap { "1", "2", "3", "4" },
+ Values { "Unknown", "Normal", "Low", "Depleted" },
+ MappingStrings { "MIF.DMTF|UPS Battery|001.1" }]
+ uint16 RemainingCapacityStatus;
+
+ [Description (
+ "TimeOnBackup indicates the elapsed time in seconds since "
+ "the UPS last switched to battery power, generator, or so "
+ "on or the time since the UPS was last restarted, "
+ "whichever is less. 0 is returned if the UPS is \'on "
+ "line\'." ),
+ Units ( "Seconds" ),
+ MappingStrings { "MIF.DMTF|UPS Battery|001.2" },
+ PUnit ( "second" )]
+ uint32 TimeOnBackup;
+
+ [Description (
+ "EstimatedRunTime is an estimate in minutes of the time "
+ "that depletion of the battery, generator, or other "
+ "device, will occur under the present load conditions if "
+ "the utility power is off or is lost and remains off." ),
+ Units ( "Minutes" ),
+ MappingStrings { "MIF.DMTF|UPS Battery|001.3" },
+ PUnit ( "minute" )]
+ uint32 EstimatedRunTime;
+
+ [Description (
+ "An estimate of the percentage of full charge remaining "
+ "for a UPS (that uses battery technology)." ),
+ Units ( "Percent" ),
+ Gauge, MappingStrings { "MIF.DMTF|UPS Battery|001.4" },
+ PUnit ( "percent" )]
+ uint16 EstimatedChargeRemaining;
+
+
+};