| Commit message (Collapse) | Author | Age | Files | Lines |
| |
|
| |
|
| |
|
| |
|
| |
|
|
|
|
|
|
|
|
|
|
| |
Samba3 tree.
This is neater, plus it avoids the need to get legal approval from SGI
to use their GPLv2-only code under GPLv3.
If/when SGI legal sort things out, we could consider adding back this
header for very old systems where linux/dqblk_xfs.h is not available.
|
| |
|
|
|
|
|
|
|
|
| |
systems. Rather than trying to fix this, it's much better just to
remove the code, as it serves no purpose at all (the message that is
generated is ignored by smbd).
This sort of parsing should really be done by PIDL generated code.
|
|
|
|
|
|
| |
alone
client and they all work with this code.
|
|
|
|
|
|
|
| |
"Get rid of the three global variables for the case semantics. I think
this is really not worth globals."
Jeremy.
|
|
|
|
| |
Jeremy.
|
|
|
|
| |
Setting version in 3.2.0 branch to 3.2.0pre1-SVN
|
| |
|
|
|
|
| |
Guenther
|
|
|
|
| |
Guenther
|
|
|
|
|
|
| |
(including some valgrind errors, uninitialized vars, etc.)
Guenther
|
|
|
|
|
|
|
| |
to the caller (winbindd_validate_cache in this case).
Next, there will be a backup handling for the tdb files.
Michael
|
|
|
|
| |
Guenther
|
| |
|
| |
|
|
|
|
| |
Thanks to Karolin Seeger (ks@sernet.de)
|
|
|
|
|
| |
The function name reduce_name is misleading, making the user believe it
changes an argument.
|
|
|
|
|
|
| |
for the validity of the given registry key name.
Michael
|
| |
|
| |
|
| |
|
| |
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
readX. Fix from Dmitry Shatrov <dhsatrov@linux.vnet.ibm.com>.
"In send_file_readX(), if startpos > sbuf.st_size, then smb_maxcnt is set
to an invalid large value due to integer overflow.
As for me, this resulted in MS Word hanging while trying to save
a 1.5Mb document."
This isn't in shipping code.
Jeremy.
|
|
|
|
| |
Michael
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
in the current registry and there is no global section in the input
file (or only global options with default values):
In that case the existing global section is now not touched. Before, it
would have been deleted and recreated empty. The new behaviour is how
other shares are treated too.
Note that since the input file is parsed by lp_load, there is currently
no way to distinguish between a section with only default parameters
and a non-existing section in net conf import.
Michael
PS: A couple of trailing white-spaces have been eliminated
and a line was broken to be not longer than 80 chars, too.
|
|
|
|
|
|
| |
eliminate "type" parameter since we store only REG_SZ.
Michael
|
|
|
|
|
|
| |
create a temporary talloc ctx for the function.
Michael
|
|
|
|
|
|
|
|
| |
to a function of its own. (for storing it in registry),
Eliminate the valtype variable : store everything as "sz".
Eliminate some trailing white spaces on the way.
Michael
|
|
|
|
| |
Michael
|
|
|
|
|
|
| |
is equal to GLOBAL_NAME.
Michael
|
|
|
|
|
|
|
| |
of the config file fails. That's enough of checking for
existence and readbility to my taste.
Michael
|
|
|
|
| |
http://article.gmane.org/gmane.network.samba.internals/32486.
|
|
|
|
| |
Use local variable of smb_flag2 instead of using the macro every time.
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
23726:
Explicitly pass down the FLAGS2 field to srvstr_pull_buf. The next
checkin will pull this up to srvstr_get_path. At that point we can get more
independent of the inbuf, the base_ptr in pull_string will only be used
to satisfy UCS2 alignment constraints.
23731:
Explicitly pass down FLAGS2 to srvstr_get_path.
Next step is to remove the bug that in the trans2 code we use the inbuf
as the base pointer to decide whether we need ucs2 alignment where we
need to use the beginning of the params buffer
23731:
Forgot one reference to inbuf
|
|
|
|
| |
Remove get_current_mid()
|
|
|
|
|
|
|
|
| |
Reduce access to the global inbuf a tiny bit. Add a struct smb_request
that contains some of the fields from the SMB header, removing the need
to access inbuf directly. This right now is used only in the open file
code & friends, and creating that header is only done when needed. This
needs more work, but it is a start.
|
|
|
|
|
|
| |
This should coalesce identical adjacent notify records - making the "too large"
bug very rare indeed. Please test.
Jeremy.
|
|
|
|
| |
Credits to Ralf Haferkamp for the discussion and help on this.
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
commit 3941269fa01038fca242a197e8d7c1f234d45ea7
Author: Gerald (Jerry) Carter <jerry@samba.org>
Date: Thu Jul 5 14:52:03 2007 -0500
Two fixes for "winbind expand groups".
(a) Update the counter for the number of new groups to resolve else
we'll only expand one group member per level and drop the rest.
(b) Don't reset the num_names counter in winbindd_ads.c:lookup_groupmem()
or we'll drop the SIDs resolved to names via cache from the resulting
list.
|
|
|
|
|
| |
to client max buf size.
Jeremy.
|
|
|
|
|
|
|
| |
When renaming a file across 2 filesystem a samba server returns
NT_STATUS_NOT_SAME_DEVICE but thius is not translated to EXDEV,
and the generic EINVAL is returned instead.
This should fix it, Jeremy or Derrel please check if this is ok.
|
| |
|
| |
|