From f995850b38916b38718b84f4b82948479a81855a Mon Sep 17 00:00:00 2001 From: Thales Lima Oliveira Date: Mon, 22 May 2017 20:17:41 -0300 Subject: Events implemented Effects on adimittance matrix and elements: ->Fault on bus; ->Generation/Load switching; ->Branch switching. --- Project/Line.cpp | 20 ++++++++++---------- 1 file changed, 10 insertions(+), 10 deletions(-) (limited to 'Project/Line.cpp') diff --git a/Project/Line.cpp b/Project/Line.cpp index 86d947c..ba56ebc 100644 --- a/Project/Line.cpp +++ b/Project/Line.cpp @@ -134,16 +134,16 @@ bool Line::AddParent(Element* parent, wxPoint2DDouble position) UpdateSwitches(); Bus* parentBus = static_cast(parent); - m_electricaData.nominalVoltage = parentBus->GetEletricalData().nominalVoltage; - m_electricaData.nominalVoltageUnit = parentBus->GetEletricalData().nominalVoltageUnit; + m_electricaData.nominalVoltage = parentBus->GetElectricalData().nominalVoltage; + m_electricaData.nominalVoltageUnit = parentBus->GetElectricalData().nominalVoltageUnit; return false; } // Second bus. else if(parent != m_parentList[0]) { Bus* parentBus = static_cast(parent); - if(m_electricaData.nominalVoltage != parentBus->GetEletricalData().nominalVoltage || - m_electricaData.nominalVoltageUnit != parentBus->GetEletricalData().nominalVoltageUnit) { + if(m_electricaData.nominalVoltage != parentBus->GetElectricalData().nominalVoltage || + m_electricaData.nominalVoltageUnit != parentBus->GetElectricalData().nominalVoltageUnit) { wxMessageDialog msgDialog(NULL, _("Unable to connect two buses with different nominal voltages.\n" "Use a transformer or edit the bus properties."), _("Error"), wxOK | wxCENTRE | wxICON_ERROR); @@ -366,10 +366,10 @@ bool Line::SetNodeParent(Element* parent) // two different voltages buses Bus* parentBus = static_cast(parent); if(!m_parentList[0] && !m_parentList[1]) { - m_electricaData.nominalVoltage = parentBus->GetEletricalData().nominalVoltage; - m_electricaData.nominalVoltageUnit = parentBus->GetEletricalData().nominalVoltageUnit; - } else if(m_electricaData.nominalVoltage != parentBus->GetEletricalData().nominalVoltage || - m_electricaData.nominalVoltageUnit != parentBus->GetEletricalData().nominalVoltageUnit) { + m_electricaData.nominalVoltage = parentBus->GetElectricalData().nominalVoltage; + m_electricaData.nominalVoltageUnit = parentBus->GetElectricalData().nominalVoltageUnit; + } else if(m_electricaData.nominalVoltage != parentBus->GetElectricalData().nominalVoltage || + m_electricaData.nominalVoltageUnit != parentBus->GetElectricalData().nominalVoltageUnit) { wxMessageDialog msgDialog(NULL, _("Unable to connect two buses with different nominal voltages.\n" "Use a transformer or edit the bus properties."), _("Error"), wxOK | wxCENTRE | wxICON_ERROR); @@ -488,8 +488,8 @@ wxString Line::GetTipText() const if(m_online) { tipText += "\n"; int busNumber[2]; - busNumber[0] = static_cast(m_parentList[0])->GetEletricalData().number + 1; - busNumber[1] = static_cast(m_parentList[1])->GetEletricalData().number + 1; + busNumber[0] = static_cast(m_parentList[0])->GetElectricalData().number + 1; + busNumber[1] = static_cast(m_parentList[1])->GetElectricalData().number + 1; tipText += _("\nP") + wxString::Format("(%d-%d) = ", busNumber[0], busNumber[1]) + wxString::FromDouble(m_electricaData.powerFlow[0].real(), 5) + _(" p.u."); -- cgit