summaryrefslogtreecommitdiffstats
path: root/Project/Line.cpp
diff options
context:
space:
mode:
Diffstat (limited to 'Project/Line.cpp')
-rw-r--r--Project/Line.cpp20
1 files changed, 10 insertions, 10 deletions
diff --git a/Project/Line.cpp b/Project/Line.cpp
index 86d947c..ba56ebc 100644
--- a/Project/Line.cpp
+++ b/Project/Line.cpp
@@ -134,16 +134,16 @@ bool Line::AddParent(Element* parent, wxPoint2DDouble position)
UpdateSwitches();
Bus* parentBus = static_cast<Bus*>(parent);
- m_electricaData.nominalVoltage = parentBus->GetEletricalData().nominalVoltage;
- m_electricaData.nominalVoltageUnit = parentBus->GetEletricalData().nominalVoltageUnit;
+ m_electricaData.nominalVoltage = parentBus->GetElectricalData().nominalVoltage;
+ m_electricaData.nominalVoltageUnit = parentBus->GetElectricalData().nominalVoltageUnit;
return false;
}
// Second bus.
else if(parent != m_parentList[0]) {
Bus* parentBus = static_cast<Bus*>(parent);
- if(m_electricaData.nominalVoltage != parentBus->GetEletricalData().nominalVoltage ||
- m_electricaData.nominalVoltageUnit != parentBus->GetEletricalData().nominalVoltageUnit) {
+ if(m_electricaData.nominalVoltage != parentBus->GetElectricalData().nominalVoltage ||
+ m_electricaData.nominalVoltageUnit != parentBus->GetElectricalData().nominalVoltageUnit) {
wxMessageDialog msgDialog(NULL, _("Unable to connect two buses with different nominal voltages.\n"
"Use a transformer or edit the bus properties."),
_("Error"), wxOK | wxCENTRE | wxICON_ERROR);
@@ -366,10 +366,10 @@ bool Line::SetNodeParent(Element* parent)
// two different voltages buses
Bus* parentBus = static_cast<Bus*>(parent);
if(!m_parentList[0] && !m_parentList[1]) {
- m_electricaData.nominalVoltage = parentBus->GetEletricalData().nominalVoltage;
- m_electricaData.nominalVoltageUnit = parentBus->GetEletricalData().nominalVoltageUnit;
- } else if(m_electricaData.nominalVoltage != parentBus->GetEletricalData().nominalVoltage ||
- m_electricaData.nominalVoltageUnit != parentBus->GetEletricalData().nominalVoltageUnit) {
+ m_electricaData.nominalVoltage = parentBus->GetElectricalData().nominalVoltage;
+ m_electricaData.nominalVoltageUnit = parentBus->GetElectricalData().nominalVoltageUnit;
+ } else if(m_electricaData.nominalVoltage != parentBus->GetElectricalData().nominalVoltage ||
+ m_electricaData.nominalVoltageUnit != parentBus->GetElectricalData().nominalVoltageUnit) {
wxMessageDialog msgDialog(NULL, _("Unable to connect two buses with different nominal voltages.\n"
"Use a transformer or edit the bus properties."),
_("Error"), wxOK | wxCENTRE | wxICON_ERROR);
@@ -488,8 +488,8 @@ wxString Line::GetTipText() const
if(m_online) {
tipText += "\n";
int busNumber[2];
- busNumber[0] = static_cast<Bus*>(m_parentList[0])->GetEletricalData().number + 1;
- busNumber[1] = static_cast<Bus*>(m_parentList[1])->GetEletricalData().number + 1;
+ busNumber[0] = static_cast<Bus*>(m_parentList[0])->GetElectricalData().number + 1;
+ busNumber[1] = static_cast<Bus*>(m_parentList[1])->GetElectricalData().number + 1;
tipText += _("\nP") + wxString::Format("(%d-%d) = ", busNumber[0], busNumber[1]) +
wxString::FromDouble(m_electricaData.powerFlow[0].real(), 5) + _(" p.u.");