*OpenLMI Fan* usage =================== Examples for common use cases listed below are written in `lmishell`_. Set up ------ *OpenLMI Fan* provider uses `lm-sensors`_ to find, observe and manage installed fans. In order to make the fans exposed to it, one operation needs to be done: .. code-block:: sh sensors-detect ``sensors-detect`` is a script shiped with ``lm_sensors`` package in *Fedora* which tries to load correct modules for various sensor devices found in system. It also writes a config used by ``sensors`` library which is utilised in this provider. Please refer to its *sensors-detect (8)* man-page. Examples -------- Listing installed fans ~~~~~~~~~~~~~~~~~~~~~~ :: c = connect("host", "user", "pass") for fan in c.root.cimv2.LMI_Fan.instances(): print(fan.ElementName) .. seealso:: :ref:`LMI_Fan` Getting fan's speed ~~~~~~~~~~~~~~~~~~~ Current value can be read from :ref:`CurrentReading` property. It's measured in *revolutions per minute*. :: c = connect("host", "user", "pass") for fan in c.root.cimv2.LMI_FanSensor.instances(): print("%s:\t%s RPM" % (fan.Name, fan.CurrentReading)) .. seealso:: :ref:`LMI_FanSensor` .. ***************************************************************************** .. _lmishell: https://fedorahosted.org/openlmi/wiki/shell .. _lm-sensors: http://lm-sensors.org/