#!/bin/bash # # clvmd - Clustered LVM Daemon init script # # chkconfig: - 24 76 # description: Cluster daemon for userland logical volume management tools. # # For Red-Hat-based distributions such as Fedora, RHEL, CentOS. # ### BEGIN INIT INFO # Provides: clvmd # Required-Start: $local_fs@CLVMD_CMANAGERS@ # Required-Stop: $local_fs@CLVMD_CMANAGERS@ # Short-Description: This service is Clusterd LVM Daemon. # Description: Cluster daemon for userland logical volume management tools. ### END INIT INFO . /etc/rc.d/init.d/functions DAEMON=clvmd exec_prefix=@exec_prefix@ sbindir=@sbindir@ lvm_vgchange=${sbindir}/vgchange lvm_vgdisplay=${sbindir}/vgdisplay lvm_vgscan=${sbindir}/vgscan lvm_lvdisplay=${sbindir}/lvdisplay CLVMDOPTS="-T30" [ -f /etc/sysconfig/cluster ] && . /etc/sysconfig/cluster [ -f /etc/sysconfig/$DAEMON ] && . /etc/sysconfig/$DAEMON [ -n "$CLVMD_CLUSTER_IFACE" ] && CLVMDOPTS="$CLVMDOPTS -I $CLVMD_CLUSTER_IFACE" # allow up to $CLVMD_STOP_TIMEOUT seconds to clvmd to complete exit operations # default to 10 seconds [ -z $CLMVD_STOP_TIMEOUT ] && CLVMD_STOP_TIMEOUT=10 LOCK_FILE="/var/lock/subsys/$DAEMON" # NOTE: replace this with vgs, once display filter per attr is implemented. clustered_vgs() { ${lvm_vgdisplay} 2>/dev/null | \ awk 'BEGIN {RS="VG Name"} {if (/Clustered/) print $1;}' } clustered_active_lvs() { for i in $(clustered_vgs); do ${lvm_lvdisplay} $i 2>/dev/null | \ awk 'BEGIN {RS="LV Name"} {if (/[^N^O^T] available/) print $1;}' done } rh_status() { status $DAEMON } rh_status_q() { rh_status >/dev/null 2>&1 } start() { if ! rh_status_q; then echo -n "Starting $DAEMON: " $DAEMON $CLVMDOPTS || return $? echo fi # Refresh local cache. # # It's possible that new PVs were added to this, or other VGs # while this node was down. So we run vgscan here to avoid # any potential "Missing UUID" messages with subsequent # LVM commands. # The following step would be better and more informative to the user: # 'action "Refreshing VG(s) local cache:" ${lvm_vgscan}' # but it could show warnings such as: # 'clvmd not running on node x-y-z Unable to obtain global lock.' # and the action would be shown as FAILED when in reality it didn't. # Ideally vgscan should have a startup mode that would not print # unnecessary warnings. ${lvm_vgscan} > /dev/null 2>&1 action "Activating VG(s):" ${lvm_vgchange} -aay $LVM_VGS || return $? touch $LOCK_FILE return 0 } wait_for_finish() { count=0 while [ "$count" -le "$CLVMD_STOP_TIMEOUT" ] && \ rh_status_q ]; do sleep 1 count=$((count+1)) done ! rh_status_q } stop() { rh_status_q || return 0 [ -z "$LVM_VGS" ] && LVM_VGS="$(clustered_vgs)" if [ -n "$LVM_VGS" ]; then action "Deactivating clustered VG(s):" ${lvm_vgchange} -anl $LVM_VGS || return $? fi action "Signaling $DAEMON to exit" kill -TERM $(pidofproc $DAEMON) || return $? # wait half second before we start the waiting loop or we will show # the loop more time than really necessary usleep 500000 # clvmd could take some time to stop rh_status_q && action "Waiting for $DAEMON to exit:" wait_for_finish if rh_status_q; then echo -n "$DAEMON failed to exit" failure echo return 1 else echo -n "$DAEMON terminated" success echo fi rm -f $LOCK_FILE return 0 } reload() { rh_status_q || exit 7 action "Reloading $DAEMON configuration: " $DAEMON -R || return $? } restart() { # if stop fails, restart will return the error and not attempt # another start. Even if start is protected by rh_status_q, # that would avoid spawning another daemon, it would try to # reactivate the VGs. # Try to get clvmd to restart itself. This will preserve # exclusive LV locks action "Restarting $DAEMON: " $DAEMON -S # If that fails then do a normal stop & restart if [ $? != 0 ]; then stop && start return $? else touch $LOCK_FILE return 0 fi } [ "$EUID" != "0" ] && { echo "clvmd init script can only be executed as root user" exit 4 } # See how we were called. case "$1" in start) start rtrn=$? ;; stop) stop rtrn=$? ;; restart|force-reload) restart rtrn=$? ;; condrestart|try-restart) rh_status_q || exit 0 restart rtrn=$? ;; reload) reload rtrn=$? ;; status) rh_status rtrn=$? if [ $rtrn = 0 ]; then cvgs="$(clustered_vgs)" echo Clustered Volume Groups: ${cvgs:-"(none)"} clvs="$(clustered_active_lvs)" echo Active clustered Logical Volumes: ${clvs:-"(none)"} fi ;; *) echo $"Usage: $0 {start|stop|status|restart|condrestart|try-restart|reload|force-reload}" rtrn=2 ;; esac exit $rtrn